Specifications | ||
---|---|---|
Model Number | DS-2XE6126FWD-HS | |
Image Sensor | 1/2.8″ progressive scan CMOS | |
Min. illumination | 0.003 lux @ (F1.0, AGC ON) | |
Shutter time | 1 ~ 1/100,000s | |
Lens | 4mm | |
Angle adjustment | Pan: 0° ~ 340°, tilt 0° ~ 75° | |
Digital noise reduction | 3D DNR | |
Wide dynamic range | True WDR 120dB | |
Day & night | Electronic | |
Video compression | H.264 / H.264+ / H.265 / H.265+ / MJPEG(substream) | |
Triple stream | Yes | |
Audio | 1/1 | |
Alarm | 1/1 | |
Max. image resolution | 1920 x 1080 | |
Frame rate | 30 FPS @ 1920 x 1080 | |
Image settings | Rotate mode, saturation, brightness, contrast, sharpness, AGC, and white balance are adjustable by client software or web browser |
|
On Board Storage | Micro SD slot, up to 128GB | |
Protocols | TCP/IP, ICMP, HTTP, HTTPS, FTP, DHCP, DNS, DDNS, RTP, RTSP, RTCP, PPPoE, NTP, UPnP, SMTP, SNMP, IGMP, 802.1X, QoS, IPv6, UDP, Bonjour |
|
API | ONVIF(Profile S, Profile G), ISAPI | |
General functionalities | One-key reset, anti-flicker, three streams, heartbeat, mirror, password protection, privacy mask, watermark, IP address filter |
|
Communication interface | 1 RJ45 10M / 100M / 1000M Ethernet interface | |
Operating conditions | -40°C ~ 60°C (-40°F ~ 140°F) humidity 95% or less (non-condensing) | |
Power supply | 12 VDC ±20%, PoE (802.3af, class 3) Terminal block for DC input |
|
Power consumption | Max, 12.5W | |
Ratings | IP68 | |
Materials | Stainless Steel 316L | |
Dimensions | Camera: Ø 138 × 123.4 mm (Ø 5.43″ × 4.86″) Package: 251 × 215 × 189 mm (9.88″ × 8.46″ × 7.44″ |
|
Weight | Camera: Approx. 2.5 kg (5.51 lb.) With package: approx. 3.46 kg (7.63 lb. |
|
Explosion-Proof | ATEX: II 2 G D Ex db IIC T6 Gb/Ex tb IIIC T80°C Db IP68 IECEx: Ex db IIC T6 Gb/Ex tb IIIC T80°C Db IP68 For explosive gas atmospheres, the maximum surface temperature is 85°C; For flammable dust atmospheres, the maximum surface temperature is 80°C; IIC: for explosive gas atmospheres other than mines susceptible to firedamp; For explosive gas mixture atmospheres: Zone 1, Zone 2, Zone 21, Zone 22. |
|
Wall Mount | HTH-697ZJ-X | |
Explosion proof conduit pipes | DS-1677ZJ-XS-1.0 | |
EMC | FCC: FCC-SDoC(ANSI C63.4,FCC Part15 sub B) CE: CE-EMC(EN 50130-4:2011+A1:2014,EN 55032:2015,EN 61000-3-2:2014,EN 61000-3-3:2013) RCM: AS/NZS 60950.1:2003 + Am1, Am2 and Am3,AS/NZS CISPR 32:2015 IC: IC-VoC(ICES-003 Issue 7:2020) KC: KN 301489-1,KN 301489-17,RRA NOTICE 2017-14(2017.12.05),RRA NOTICE 2017-19(2017.12.28) |